Fuji Online Ups
1) Finch PW
Finch PW ensures that equipment functions without power interruptions when power quality is questionable and outages are frequent. Finch PW adjusts to charging current from 1A to 6A depending on the requirement and with an additional charger, Finch PW can support longer backup times. It is ideal for ATMs, banking, and other business-critical applications where long backup periods are essential.
Built-in Batteries: 1kva 24Vdc, 2Kva 96Vdc, 3Kva 96Vdc, 6Kva 192Vdc
Long Run Model: 1Kva 36Vdc, 2Kva 72Vdc, 3Kva 72Vdc, 6Kva 192Vdc, 10Kva 192Vdc
Features & Benefits
- Online double conversion UPS.
- Input power factor corrector
0.99 (PFC)
- Automatic bypass, allow to
transfer the load to the mains in case of overload or internal fault
- Inbuilt Isolation Transformer
(optional) provides a galvanic isolation between the mains and the loads
- Hot standby Configuration to
ensure the availability of Quality power to mission critical applications
- Battery cold start feature
allows UPS to be powered on from the battery without utility
2)Finch PG
Finch
PG with dual mains inputs is designed with DSP technology and active input
power factor correction to ensure better output voltage. This ensures better
power quality and performance at all times. Finch PG is a double-conversion
online UPS with an output power factor of 0.9 providing higher power density
and delivers 12.5% more power when compared with conventional UPS (designed
with output power factor of 0.8). It has an automatic bypass that allows the
transfer of load to the mains in case of overloads or internal fault. It is
configurable both as a Single-Phase input & Output or Three Phase Input and
Single-Phase output on 10 kVA
3Ph
in : 1Ph Out
10Kva
240Vdc, 20Kva 240Vdc
3Phase
input: 3Phase Output
10Kva
240Vdc, 20Kva 240Vdc, 30Kva 240Vdc
Features & Benefits
- Online double conversion UPS.
- Input power factor corrector
0.99 (PFC)
- Automatic bypass, allow to
transfer the load to the mains in case of overload or internal fault
- Output Power factor of 0.9
- Configurable as Single Phase
Input & Output or Three Phase Input and Single Phase output on 10kVA
- Hot standby configuration to
ensure the availability of quality power to mission critical applications
- Battery cold start feature
allows UPS to be powered on from the battery without utility
- Can be paralleled upto 3 units
for capacity and/or redundancy
- Flexible/settable battery
configuration
3)Falcon 8500
Falcon
8500 range of Three Phase Online UPS systems are designed and built to function
in the critical network and cloud environments maintaining both data security
and business continuity. With a 32-bit DSP controlled UPS, the unique modular
design and compact footprint comes with variety of special features including
true RMS reading of more than 25 parameters, advanced thermal design and
monitoring functions as well as inbuilt galvanic isolation.
3Phase
input: 1Phase Output
10Kva
360Vdc, 20Kva 360Vdc, 30Kva 360V360Vdc
3Phase
Input: 3Phase Output
10kva
384Vdc, 20Kva 384Vdc, 30Kva 384Vdc, 40Kva 384Vdc, 60Kva 384Vdc
Features & Benefits
- 32 bit DSP controlled UPS
- Inbuilt galvanic isolation
- Space vector modulation
technique
- 128 x 64 Graphics Display
- True RMS reading of more than
25 different parameters of UPS
- Quiet operation, low audible
noise
- Superior output quality ;
Output voltage distortion < 1%*
- Unique modular design, offering
lowest MTTR
- Compact system, lowest
footprint to kVA ratio in its category
- High end interfacing options
- Advance thermal design and
monitoring